HUAYI Automatic Gas Odorization System is designed for controlled injection of liquid odorant into natural gas transmission and distribution systems. The system receives the gas flow signal and adjusts the odorant injection rate according to changes in gas flow, helping maintain the required odorization level under varying operating conditions.

The system can be configured with single or dual metering pumps, odorant storage tanks, control cabinet, level indication and related piping and instrumentation. Automatic flow-proportional control and manual adjustment can be provided according to project requirements.

Typical applications include natural gas gate stations, pressure regulating and metering stations, city gas distribution systems and industrial natural gas supply systems.

Detail

Product Overview

HUAYI Automatic Gas Odorization System is designed to inject a controlled quantity of liquid odorant into a natural gas stream. The system can receive a gas flow signal from the upstream metering system and automatically adjust the odorant injection rate according to changes in gas flow.

The equipment can be configured according to project-specific gas flow, operating pressure, odorant type, dosing requirements, control philosophy and site conditions.

Main System Components

  • Odorant metering pump

  • Odorant storage tank

  • Control cabinet

  • Liquid level indication and calibration arrangement

  • Odorant injection piping and fittings

  • Pressure and flow control components

  • Electrical and instrumentation components

  • Gas pipeline connection and odorant injection interface

The detailed configuration can be customized according to project requirements.

Reference Technical Parameters

ParameterReference Configuration
System ConfigurationSingle-pump or dual-pump automatic odorization system
Working Pressure0.2–1.4 MPa
Metering PumpMilton Roy or project-specified equivalent
Reference Pump ModelsP746 / P621
Odorant Injection Capacity0.022–2.2 L/h
Reference Gas Flow RangeUp to 110,000 m³/h, depending on configuration
Power Supply220 V
Reference Power22 W
Pump Frequency1–100 strokes/min, adjustable
Odorant Tank Capacity60 L / 90 L / 200 L / 270 L
Gas Pipeline InterfaceDN20 flange
Control Signal4–20 mA flow signal
Reference OdorantTetrahydrothiophene (THT)

Note: The above values are reference parameters based on an existing configuration. Final specifications shall be determined according to project operating conditions and technical requirements.

Automatic Odorant Injection

The control system can receive a 4–20 mA gas flow signal from the external flow measurement system. The signal is processed by the controller to regulate the operation of the metering pump, allowing the odorant injection rate to follow changes in natural gas flow.

Manual adjustment can also be provided according to the selected control configuration.

Odorant Metering and Storage

The system can be equipped with stainless steel odorant storage and measuring components. Liquid level indication and calibration arrangements can be incorporated to support operation, inspection and adjustment of the odorant injection system.

Tank capacity and configuration can be selected according to the required odorant consumption, operating period and project requirements.

Safety and Control

Depending on the project requirements and installation area, the odorization system can be configured with appropriate electrical, instrumentation and safety components for the specified operating environment.

Explosion-protection requirements, hazardous-area classification, electrical protection level and applicable certification requirements should be confirmed during project engineering.

Typical Applications

  • Natural gas gate stations

  • Gas pressure regulating and metering stations

  • City gas distribution systems

  • Industrial natural gas supply systems

  • Natural gas transmission and distribution facilities

Customized Engineering

HUAYI can configure the gas odorization system according to project-specific requirements including:

  • Natural gas flow range

  • Pipeline operating and design pressure

  • Required odorant dosing rate

  • Odorant type

  • Metering pump configuration

  • Odorant storage capacity

  • Automatic or manual control requirements

  • Flow signal and communication interface

  • Power supply

  • Hazardous-area requirements

  • Pipeline connection requirements

Please provide the gas flow range, operating pressure, odorant type, required dosing rate, electrical supply and control signal when requesting a technical proposal.